<< Click to Display Table of Contents >> Navigation: The Light-O-Rama Software Package > Control Panel > Networks > Art-Net Controller |
On this screen you define a group of DMX universes for a controller that uses the Art-Net protocol.
Use the name field as you see fit. Listing some of the key props on this network makes for a good name.
The first DMX universe used by this controller.
The last DMX universe used by this controller.
Turn this setting on for PixCon16 controllers.Turn it off for Aurora Core and PixieLink controllers. If you are using a third-party Art-Net controller, testing on your part may be required (if this setting is incorrect, data will be one universe off).
Here, you must select the type of IP address you wish to use for this controller:
•Specify: Selecting this option will cause the universe to use unicast mode, and lighting commands for the universe will be received by a single Art-Net device, using the IP address that you specify.
•Local: This option will cause the universe to send lighting commands to the computer itself, using the local loopback address (127.0.0.1).
The IP port that the remote device or devices will listen on for lighting commands should be specified here. In almost all cases, the standard value (6454) should be appropriate.